EtherCAT I/O Devices

Modules with EtherCAT interface for the acquisition/generation of peripheral signals.

Common data:

  • EtherCAT ports: 2
  • power supply: 24V+-30%
  • housing: 120 x 101 x 22.5 mm
  • mounting: DIN rail assembly
  • IO-signals are ohmic isolated from logic circuit

Products:

  • Counter Module
    • 4 channels ABZ, max. 2MHz per track
    • high precision frequency measurement or period duration measurement or counter
    • quadrature mode or A forward + B backward or pulse + direction
  • Analog Input Module
    • 8 channels, 13bit, 25us
    • programmable input range: +-10V, +-5V, +-2.5V, 0..10V
  • Analog Output module:
    • 8 channels, 12 (14, 16)bit, 30us
    • programmable output range: +-10V, +-5V, 0..10V, 0..5V
  • SSI Module
    • 2 channels
    • programmable dataword length 1..32bit
    • gray or binary coded
    • 125/250/500kHz, 1MHz
  • Binary Input Module
    • 32 channels
    • 24V inputs, other on request
    • 2mA constant input current
    • input filter with defined delay for noise reduction
  • Binary Output Module
    • 16 or 32 channels
    • 24V outputs
    • until 1A per channel
    • reverse polarity protection
  • Analog Input Module (under development)
    • 8 channels, 16bit, approx. 25us
    • input range: +-10V, (+-5V)
  •  

 